56
SESAMO
SMARTPRO
11
Impulse duration of
the electric lock or
Opening delay
RANGE: 0 ÷ 9
Timing depends on the type of electric lock:
please refer to paragraph “electric locks setting”
2
12
Lock closing force
RANGE:
0(min.) ÷ 9(max.)
5
13
Single/Master/Slave
0 = Single
1 = Not used
2 = Not used
3 = Double Master
–
wiring CAN cable
4 = Double Slave
–
wiring CAN cable
0
14
Activation of the
electric lock or
motor closing
according to the
logic selected
0 = Disabled
1 = One Radar OUT
2 = Two Radar, One Radar IN.
3 = Always (1 Radar IN, 1 Radar OUT, 2 Radar)
3
15
Auxiliary input
configuration 1
AUX-IN 1
0 = DDA opening
1 = Emergency opening
2 = Interlock door with priority
3 = Interlock door without priority
4 = Feedback lock release
5 = Command lock release
6 = Command Single on Double door operation
7 = Stand-by
8 = Reactivate the door after stand-by
9 = step/step function (1 impulse open, 1 impulse close)
10 = Fire alarm opening
11 = Setting manual logic
12 = Setting Stop Closed logic
13 = DDA opening in manual operation
14 = step/step function with automatic closing (idle time in
minutes and not seconds)
15 = Contact Door in closed position
16 = Opening Total or Partial.
0
16
Auxiliary input
configuration
AUX-IN 2
0 = DDA opening
1 = Emergency opening
2 = Interlock door with priority
3 = Interlock door without priority
4 = Feedback lock release
5 = Command lock release
6 = Command Single on Double door operation
7 = Stand-by
8 = Reactivate the door after stand-by
9 = step/step function (1 impulse open, 1 impulse close)
10 = Fire alarm emergency opening
11 = Setting manual logic
12 = Setting Stop Closed logic
13 = DDA opening in manual operation
14 = step/step function with automatic closing (idle time in
minutes and not seconds)
15 = Contact Door in closed position
16 = Opening Total or Partial.