![Sesamo smart PRO Operating Instructions Manual Download Page 63](http://html1.mh-extra.com/html/sesamo/smart-pro/smart-pro_operating-instructions-manual_1247168063.webp)
63
SESAMO
SMARTPRO
27.
WIRING AND USE DOUBLE
S
MART
P
RO
(S/M)
ATTENTION!!!! Before wiring the two operator MASTER and SLAVE operator by be chosen. By convention
MASTER door is always the first that opens and the last that closes while SLAVE door is the last in
opening and the first that closes. MASTER control board process the operating logics while SLAVE control
board executes the commands of the MASTER.
Wire the two operators as indicated before with the sync cable.
B
–
Without overlapping of the doors
A
–
With overlapping of the doors
Master
Slave
Sync cable
CAN = ON
Master and Slave