26.
OPERATING LOGICS
Con interruttore logiche montato in testata:
With basic selector (optional) (3 position switch is disabled):
LOGIC
DESCRIPTION
Manual
In this logic the devices connected to START 1 and START2 are disabled. Opening and
closing are in manual mode. Safety sensor in opening and closing are working only in
motor opening by DDA mode (disabled people).
1 radar
RADAR ONLY EXIT: Only START 2 is detected. A signal coming from a sensor command
an opening cycle and following a closing cycle. The door locking by electric-lock or
motor (in case none electric-lock has been set) in the closed position depends on the
type of lock used and from the setting of parameter 14.
2 radar
RADAR IN and OUT: Both contacts START1 e START2 of the control board are
detected. A signal coming from a sensor connected to one of those input gives the
signal to open the door and then close. The door locking by electric-lock or motor (in
case none electric-lock has been set) in the closing position depends on the type of
lock used and from the setting of parameter 14.
Stop close
Door is kept in closed position. Operator gives a command to close the door. In this
logic input START1 e START2 of the control board are not detected; if installed, the
electric-lock blocked the door. If there is not any electric-lock, the motor will keep the
door in closed position.
Stop open
Door is kept in open position. Operator gives a command to fully open and keep
opened the door. In this logic input START1 e START2 of the control board are not
detected.
Stop closed
Automatic
Stop open
Automatic
Stop open
Manual