78
SESAMO
SMARTPRO
INSTALLATION
WITH
BASIC
SELECTOR
Stop Close
: the automatism controls the complete closure of the door wings. In this logic the inputs START1 and
START2 of the electronic control card are not monitored; if present, the electric locking system blocks the door wings.
•
Stop Open
: the automatism controls the complete opening of the door wings. In this logic the inputs START1 and
START2 of the electronic control card are not monitored.
•
2 radar (Entry-exit radar)
: both the inputs START 1 and START 2 of the electronic control card are monitored. A
signal originating from a sensor connected to one of these inputs triggers the opening and consequent closing of the
door wings. The electric locking system, if present, never blocks the door wings.
•
1 radar (Exit-only radar)
: only the input START 2 of the electronic control card is monitored. A signal originating from
a sensor connected to this input triggers the opening and consequent closing of the door wings. The electric locking
system, if present, blocks the door wings every time that these reach the position of complete closure.
•
Manual opening
: the automatism controls the complete closure of the door wings. In this logic the inputs START1
and START2 of the electronic control card are not active.
The automatism makes an opening and closing only and exclusively in the following cases:
•
When you press the manual opening control, and if the electric locking system is not installed, with the "push
and go" when activated.
The led indicators indicate the logic currently active (led lit up). To change the logic, press the SELECT key; every time
the key is pressed the led corresponding to the various logics lights up in sequence. When the desired logic is reached,
the led blinks for a few seconds; when the light remains on, the control card acquires the new logic.
The Battery LED signal lights to indicate the absence of power supply and the resulting battery operation automatism.
In addition, the flashing of the LED indicates low battery power.
1
Logic manual opening
2
Stop close
3
Stop open
4
1 Radar
5
2 Radar
PR
Manual opening push button
ESC
Esc
RESET Reset
Battery mode