47
SESAMO
SMARTPRO
6-
MAGLOCK WITH
DELAY RELOCK
10
6
Magnet that is powered keeps the door closed, if
disconnected it release the door. It does not require
a push back hit to unlock the door. Magneti s
powered again only when the door is completely
closed.
11
RANGE: 0÷9
[t=200÷2000 ms]
(
1
) It is possible to use electric lock 12 and 24 VDC (Parameter 09) maximum power supply di 500mA
. For
maglock use only 24VDC.
(
2
) Compatibility with following types of electric locks:
(
3
) For some type of electric-lock it is possible to modify the duration of the impulse for activation or the
delay of the opening from the unlock command. This parameter has different meaning and adjustment
range setting according to the model of electric-lock set with parameter 10.
(
4
) To ensure the closing of the electric-lock is possible to adjust the closing force.
(
5
) È
possibile limitare l’utilizzo della serratura (per le tipologie di serrature 2
-3-4-6) solo se sono selezionate
determinate logiche di funzionamento.
(
6
) È possibile gestire un comando di feedback dalla serratura che ne indica la condizione di sblocco: dopo
aver dato il comando di sblocco la centrale elettronica attende il consenso dalla serratura prima di iniziare
l’apertura. Se questo non arriva entro un tempo massimo impostato, l’automatismo apre comunque la
porta.
(
7
) È possibile di utilizzare uno degli ingressi ausiliari come comando di sblocco manuale della serratura che
lavora in parallelo al comando di sblocco automatico, utilizzabile per aprire la porta in modalità manuale.