SIE-CNTEP-1100002104-2014
LCFS
AV6418 OTDR
41
(1) Event Type:
: indicates this event point is down event point.
: indicates this event point is up event point.
: indicates this event point is reflection event point.
: indicates this event point may be the end of optical
fiber.
(2) No: The serial number of current event point.
(3) Dis (km): The distance between this event and reference
origin.
(4) Average (dB/km): The average loss of the optical cable
before the current event point.
(5) Splice Loss (dB): The splice loss measured at current
event point * indicates the current tested splice loss value is
larger than the set pass threshold of splice loss.
(6) Reflection Loss (dB): The reflection loss measured at
current event point * indicates the current tested reflection
loss value is larger than the set pass threshold of reflection
loss.
(7) Link (dB): The total loss of the fiber section from current
Página No.53 LCFS
CONVALIDACIÓN DE ERRORES DEL PROCESO:
“ADQUISICIÓN DE OTDR (OPTICAL TIME DOMAIN REFLECTOMETER) – REDES GPON/
FTTH/ SDH"