SIE-CNTEP-1100002104-2014
LCFS
AV6418 OTDR
146
breakage.
Type of optical
fiber splice
does not match
End type of the optical
fiber splice tested
must
match with that of the
OTDR light output
splice.
Otherwise it must use
the patch cord for
switch
over.
12.1 Trace test and failure cause analysis
If the result of trace test and analysis is widely different from
expected, or the expected result is not achieved, it may be
caused by one of the following:
Ø
Failed to obtain the test trace of optical fiber
If the test trace only shows front end reflection peak, but
fails to obtain the linearity trace which may reflecting
characteristics of optical fiber, please check:
l
If the type of tested fiber end matches with the type of
fiber end at OTDR optical output port.
l
If the fiber end is polluted.
l
If the optical output flange of OTDR is cracked.
l
Check the near end of tested fiber link for high loss with
the VFL function.
Página No.158 LCFS
CONVALIDACIÓN DE ERRORES DEL PROCESO:
“ADQUISICIÓN DE OTDR (OPTICAL TIME DOMAIN REFLECTOMETER) – REDES GPON/
FTTH/ SDH"