Part 1—The Diviner 2000 display unit and probe
Accessing Diviner 2000 data
Page 24
ACN 007 916 672
Sentek Pty Ltd
2.
Press
PREVIOUS
.
The
Table
mode (Single) screen displays.
Ø
To set the Full, Refill and Mark points in summed table mode
1.
Select
Profile
and change if required by:
•
using the
NEXT
and
PREVIOUS
keys or
•
typing the soil profile ID number using
the numeric key pad.
2.
Select
Data time/date
.
3.
Use the
NEXT
and
PREVIOUS
keys to scroll through each data set
recorded.
4.
Use the arrow key
to scroll across the depth intervals and highlight
Data, Full, Refill
or
Marker
.
When
Full
is highlighted, you can enter a full point for each individual
depth using a combination of the number and arrow keys.
5.
Press
ENTER
after typing the desired value.
6.
If you make a mistake, use
the
DELETE
key
to clear the last character
entered.
7.
Use steps 7–9 to alter/enter
Refill
and
Marker
points.
8.
Select another mode.
Note:
The default depth for the single and summed graph can be set in
Table mode.
9.
Select the desired depth and press
ENTER
.
From now on this depth will be displayed when you access single or
summed graph.
Graphs (single and summed)
Like the table presentation, graphs can be viewed in single and summed
formats. However rather than working in a single mode with a toggle
between single and summed, you use two modes which are accessed
through
SINGLE
and
SUMMED
mode keys.
Single mode
allows you to
view the soil moisture content at a particular depth over time;
summed
mode,
the changes in total soil moisture content over time.
Single mode
In
Single mode
the data displayed relates to a single depth on the soil
profile.
Note:
SINGLE
appears at the top of the screen.
Summary of Contents for Diviner 2000