Part 1—The Diviner 2000 display unit and probe
Measuring the soil moisture content
Sentek Pty Ltd
ACN 007 916 672
Page 19
7.
Enter the soil type number using the
numeric key pad
.
The
‘A Constant’
is highlighted.
8.
Use the
numeric key pad
to enter a value.
9.
Press
ENTER
.
10.
Repeat for constants
'B'
and
'C'
.
11.
Use the
arrow keys
to move across to different depths.
Note:
A soil type once entered, cannot be modified or deleted using the
DELETE
key. A soil type, i.e. #01..., is deleted when it is not used by
any stored profile.
The probe length is set when the first measurement is made.
Measuring the soil moisture content
When your access tubes have been installed, you are ready to use the
Diviner 2000
to measure soil moisture content. Refer to the Access Tube
Installation Guide or your local distributor for details on how to install your
access tubes.
You use one of two modes to record the soil moisture data:
•
scan—automatically takes readings at 10 cm intervals and the data
is recorded by the display unit
•
continuous—reading at any depth but the recording is manual so
you need to write down the readings.
Scan mode
Figure 8—Scan screen
SCAN MODE
Profile
01
Time
09:33
Date
03-June-1999