No.15S103-01
38/65
STC-MBS510U3V / STC-MCS510U3V / STC-MBS322U3V / STC-MCS322U3V
Specifications and Use
’s guide
The User Output outputs the High or Low level signal that was configured on the software.
Setting Procedure
Selects Line N(N: any number from 0,1,2)
1) Sets the User Output N(N is Line number) as Line Source
2) Selects User Output N(N is same as selected Line number on User Output) on User Output Selector
3) Sets the value (
True: High level, False: Low level
) on User Output Value
Monitor the status on output port.
Monitor the output voltage level High (Line Status: true) or Low (Line Status: false) through the software.
Some selectable functions can be modified in order to add to the duration or pulse width on Line Source.
The configurable parameters are shown in the chart below.
Please refer to Line Source for the applicable functions of Parameters.
GenICamParameters
TriggerOutDelay
Integer Type Trigger Out Delay
Range: 0 to 262,143usec, Default: 0usec
TriggerOutOnTime
Integer Type Trigger Out On Time
Range: 4 to 262,143usec, Default: 32usec
StrobeOutDelay
Integer Type Strobe Out Delay
Range: 0 to 262,143usec, Default: 30usec
StrobeOutOnTime
Integer Type Strobe Out On Time
Range: 4 to 262,143usec, Default: 32usec
6.3 Hardware Reset
Hardware reset can be done through CAM_RESET port.
Sets on (Default : Off) on Line Device Reset Mode, and rest the camera to apply the Low voltage in 5 sec on
CAM_RESET port.