No.15S103-01
34/65
STC-MBS510U3V / STC-MCS510U3V / STC-MBS322U3V / STC-MCS322U3V
Specifications and Use
’s guide
6
IO Function
This chapter describes the IO functions.
In this
chapter the IO Port will be described as “Line”. The follow chart details the relationship of the Line and IO Port.
IO Port
Pin No.
Signal Name
Line number
2
GPIO2
Line2
3
GPIO1
Line1
4
GPIO0
Line0
GenICam Parameters
LineSelector
IEnumeration
Type
Select Line
LineMode
IEnumeration
Type
Switch input output direction into the Line that was selected on
LineSelector.
Input: set as input, Output: set as output
LineInverter
IBoolean Type
Switch polarity inversion ON/OFF into the Line that was selected on
LineSelector.
False: polarity inversion OFF (Active-H)
、
True: polarity inversion ON
(Active-L)
LineStatus
IBoolean Type
Line Status (High/Low)
LineSource
IEnumeration
Type
Set function into the Line that was selected on LineSelector
UserOutputSelector IEnumeration
Type
Select UserOutput
UserOutputValue
IBoolean Type
Switch voltage level of UserOutput that was selected
UserOutputSelector
False: Low voltage level, True: High voltage level
6.1 Input Port Function
This functions sets the input on Line Mode, then assigns Line as the input.
The following functions can be assigned as input.
This sets the chosen port on the Trigger Source, then the input signal on the port can be assigned as Trigger.
The input signal can be switched to Active-Low(Line Inverter: true) or Active-High(Line Inverter: false) .
(*) When the Line polarity on Line Inverter is changed, this action will deal with the
trigger input’s transition
inside of camera.
This function monitors the signal status on the input port.
The High level (Line Status: true) or Low level (Line Status false) status can be seen through the software.
Summary of Contents for STC-MBS322U3V