No.15S103-01
16/65
STC-MBS510U3V / STC-MCS510U3V / STC-MBS322U3V / STC-MCS322U3V
Specifications and Use
’s guide
Precautions
*1 The procedure used to measure Sensitivity is as follows:
Measure the luminance when white level achieved 100% on F5.6
*2 Please refer to section ROI for further details on the ROI.
*3 Binning & Decimation cannot work simultaneously.
*4 The Binning & Decimation units do not change.
*5 The user should not input the trigger more frequently than the maximum frame rate.
If the trigger was input during the sensor ReadOut timing, ReadOut will be interrupted. This trigger will cause the
exposure to end.
*6 Start/Stop trigger mode is only available for the software trigger.
*7 When using this camera with a USB 2.0 port, the user should take precautions in regards to power consumption
due to this camera operating on the USB 3.0 standard.
How to obtain full frame rate
This general guideline may help the user obtain the full frame rate from the camera.
To obtain the full frame rate, the data transfer speed on the USB bus depends on the capability of the host
controller.
Renesas / Fresco Logic‘s host controller improved the data transfer speed drastically in the second generation.
Intel’s chipset increased the transfer speed 10% to 20%.
When PCIExpress board of USB3.0 interface is used, please insert the PCIExpress Gen2.0(5.0[GT/s]) slot. If non-
PCIExpress Gen2.0(5.0[GT/s]) is used, data transfer speed could decrease by about 50%.
If an incapable host controller causes a lower frame rate, the camera frame rate should be set lower than the
maximum to adjust for the incapable host controller spec. This may resolve the issue.
Due to the huge data transfer, PC resources may be consumed during the process. If this occurs, the frame rate
of the camera may be effected.
Camera Setting
Environment
Parameter
Setting
Parameter
Setting
Gain Up
0 db
Light Source
Light Box(White)
AGC
OFF
Color temperature
5100K
White Balance
Optimum
Exposure Time
1/30
Electrical Shutter
1/30
F on Lens
F
5.6
Black Level
Optimum
Target Luminance
Illuminometer
Gamma
Factory Setting