INSTALLATION AND OPERATION INSTRUCTIONS — PERSONAL ALARM SYSTEM
18
3.1.8
After the field devices are connected but before connection to the PARC-3
units or the central control point, again test each conductor for shorts to ground or the
conduit system. If this test is acceptable, you may finish the system connections.
3.1.9
Recommended wiring types and manufacturers are listed below. The wire
listed has been tested and certified for use with this system. If other wire is selected,
verify that specifications are comparable to the wire listed.
3.1.9.1 Wiring from 03RM receiver to PARC-3 transponder; 3 individually
shielded twisted pairs (shields should be drain wire type), #22 AWG stranded
conductors in overall jacket. Belden Catalog No. 8777, West Penn Catalog No.
431, or equivalent.
3.1.9.2 Wiring from PARC-3 transponder to central control; 2 individually
shielded twisted pairs, #18 AWG stranded conductors in overall jacket. Belden
Catalog No. 9368, West Penn Catalog No. 440, or equivalent. See Note.
NOTE: If special cable conditions exist, such as high moisture
conditions or multiple data cables in a single conduit, consult the
factory for alternative cable specification.
3.2
Receiver (03RM) Installation
3.2.1
The receiver has a depth of approximately 1-1/4 inches, so a deep mounting
box with a minimum 2-inch depth is required. Critical mounting dimensions are shown
in Figure 3-1. Typical mounting boxes are as follows:
4” square, w/two-gang ring (Bowers #4-SDW and #408 or equivalent)
4” square, two-gang box, 2-1/8” deep (Bowers #132-W or equivalent)
NOTE: A mounting box deeper than 2-1/8" is recommended for the 03RM/IV
for additional cable clearance.