INSTALLATION AND OPERATION INSTRUCTIONS — PERSONAL ALARM SYSTEM
2.4.4
The PARC-3 card contains jumpers for selecting the number of PAS zones
connected. This is important since the transponder reports all active alarms and
monitors all tamper inputs.
2.4.5
A 12 volt test output can initiate a self-test of 03RM receivers upon command
from central control. The 12 volt test input is received by the 03RM, which activates the
self-test circuit.
2.4.6
Each PARC-3 circuit card contains four remote alarm outputs for use as local
alarm activation, one for each receiver zone. This output can be used to signal a local
zone light or audible alarm. Only limited current is available.
2.4.7
Power for each PARC-3 is normally provided from a local power supply such as
the UPS-PFI. The local power supply powers the PARC-3 and all connected 03RM
receivers.
2.4.8
Audio features are selected by configuring jumpers on the PARC-3 card. Audio
from any zone can be provided (1) on alarm only; (2) on alarm and on command from
the MX 2000 or DCU; (3) on command from the MX 2000 or DCU only; or (4) disabled
entirely. The selection is made independently for each zone. Video output follows the
audio output configuration with the PARC-3/IV card.