![SENSTAR FPS-3 Installation & Operation Manual Download Page 7](http://html.mh-extra.com/html/senstar/fps-3/fps-3_installation-and-operation-manual_1244245007.webp)
1
INSTALLATION AND OPERATION INSTRUCTIONS — FENCE PROTECTION SYSTEMS
FENCE PROTECTION SYSTEMS
1
QUICK START
Qualified technicians may follow these simplified procedures to install and test the FPS-3 Fence
Protection System. Prerequisites for using the quick start procedures are:
•
Attendance at one or more
Magal-Senstar
FPS-3 training class.
•
Prior MX-5000 or MX-5300 field installation experience.
Before proceeding, VERIFY
that you have a complete site layout showing zone extents, processor
locations, and conduit interconnections. If you are not familiar with any of the procedures described in
this section, refer to the appropriate manual for more detailed information.
IMPORTANT PROCEDURES
Throughout the installation it is very important that certain procedures are observed:
Install ground rods and proper grounding at the MX-53OO, all FPS-3 fence-
mounted pre-amps, and all microwave locations.
Use only the approved multiconductor shielded cable for connecting the
MX-
5300 FPS-3 Central Controller to the FPS and MPS units.
Terminate wiring and shields
exactly
as shown. Improper terminations will cause
system noise and degrade performance.
The FPS-3 Central Controller must be installed within 100 feet of the MX-5300.