A-1
INSTALLATION AND OPERATION INSTRUCTIONS — FENCE PROTECTION SYSTEMS
ADDENDUM
Field Performance Analyzer
The Field Performance Analyzer, or FPA, is the FPS-3 companion test unit which allows you to rapidly
troubleshoot and adjust the FPS-3 system. See Figure A-1.
The FPA is provided with an AC transformer, internal batteries, and cables for performing field tests on
FPS-3 dual zone pre-amps. The FPA has a storage compartment for the FPS-3 pre-amp interconnect
cable.
The following is a brief description of the FPA operation.
FPS-3 Two Zone Tester Operation
Alarm
(No Auto ACK/Reset)
Red alarm LED flashes, beeper oscillates, green LED extinguished, and respective alarm
relay activates.
Operator pushes ACK/RESET button for respective zone.
Red LED goes on steady, beeper is quieted.
Operator pushes ACK/RESET again to turn red LED and relay off and re-light green LED.
Alarm
(Auto ACK/Reset)
Red alarm LED flashes, beeper oscillates, green LED extinguished, and respective alarm
relay activates all for approx. 3 seconds.
At end of alert period, zone is reset; relay deactivated, and if zone is secure red LED goes off,
and green LED goes on.
If at end of alert period zone is still in alarm, red LED goes to steady on and green LED
remains off. When alarm condition is gone the red LED goes off and green comes on automati-
cally.
Tamper
(No Auto ACK/Reset)
Red tamper LED flashes, beeper oscillates, green LED extinguished, and tamper relay
activates.
Operator pushes ACK/RESET button for respective zone.
Red LED goes steady, beeper is quieted.
Operator pushes ACK/RESET again to turn red LED and relay off and re-light green LED.
Tamper
(Auto ACK/Reset) – same as alarm (auto ack/reset) condition except tamper LED and
relay are activated.