A-2
INSTALLATION AND OPERATION INSTRUCTIONS — FENCE PROTECTION SYSTEMS
FPS-3 Tester Switch Functions
ACK/RST
- Acknowledges and resets alarms and tampers.
Off/On
– This switch turns off power to DC-DC converter.
Auto ACK
– Auto ack/reset function acknowledges and resets alarms and tampers automati-
cally after about
3
seconds. (Reset occurs provided the condition has cleared.)
Audio 1
–
Switches audio from zone 1 on. Zone 1 green LED flashes.
Audio 2
– Switches audio from zone 2 on. Zone 2 greed LED flashes.
Test Zones
–
Initiates self-test of both zones.
Gain
– Four position binary code dipswitch controls the signal sensitivity level. Sensitivity is set
from 1 to 10 with 1 being the lowest setting and 10 being the highest.
Count
– Four position binary code dipswitch that sets the number of impulses required to
produce an alarm. Count is set from 1 to 10.
Volume
– Controls the volume level of the alert tone and audio output signal.
FPS-3 Tester Zone Testing
Operator pushes and releases TEST button.
Test button interrupts power to FPS-3 Pre-Amp initiating self test on re-activation.
Tester/Annunciator indicates alarm accordingly.
Operator can listen to test pulses by activating the audio output of either zone or both.
FPS-3 Tester Audio Functions
Alert tone volume is adjustable via pot located on the circuit board inside the chassis.
Combined audio (alert tone and zone audio) volume is adjustable via panel mounted
volume control.
FPS-3 Tester Power
External power is provided by a plug-in 16.5 VAC, 20VA transformer.
Internal power is provided by a 12V, 1AH gel cell.
Operating power is provided by a DC-DC converter producing 14 VDC from either 12V
battery (external power disconnected) or 16.5 VAC, 20VA transformer. Current load is
100mA.