INSTALLATION AND OPERATION INSTRUCTIONS — FENCE PROTECTION SYSTEMS
30
Figure 32. Helisensor/Sensor Cable Termination - Single Run
Connections.
Mount each condulet slightly above the line of Helisensor to create a drip loop to prevent
moisture buildup at condulet terminations.
For remote mounted pre-amps, follow instructions in “Pre-amp Mounting” (page 26) through
“Pedestal or Wall Mounting” (page 28) sections (see Figures 24-25) and terminate Helisensor to
bell box.
INSTALL GROUND ROD
PER NATIONAL ELECTRICAL CODE
SIGNAL WIRING IN CONDUIT
TO CONTROL POINT.
NOTE:
SIGNAL CONDUIT CAN
OFTEN BE INSTALLED ON THE
FENCE.
DUAL
ZONE
PRE-AMP.
UNISTRUT TYPE
MOUNTING
1/2” FLEXIBLE
CONDUIT
TERMNATIONS
MOISTURE
DRIP LEG
BOTH ENDS OF DOUBLE RUN HELISENSOR
INSTALLATIONS ARE TERMINATED TO THE
PRE-AMP. ENCLOSURE
NOTE: