INSTALLATION AND OPERATION INSTRUCTIONS — FENCE PROTECTION SYSTEMS
For end-of-line termination, attach sensor cable to terminals as shown in Figure 36. Clip jumpers 2 &4.
For double end-of-line terminations, attach sensor cables to both terminals.
Helisensor is provided in standard 100 meter lengths. Some applications may require longer zone
lengths. The additional length is threaded into the condulet and the transducer cable is connected as
shown in Figure 37. Clip jumpers 1 & 3.
Figure 36. End-of-Line Termination
Figure 38. End-of-Line Termination With 2 Megaohm Resistor
Figure 37. Splice Termination
In cases where the transducer cable is “T” tapped as in applications involving Telegates for gates, it is
necessary to provide for supervision of both cables. This requires a 2 megaohm resistor at both the “T”
section and the normal end-of-line. Attach the sensor cable as shown in Figure 38 and clip jumper 2.