INSTALLATION AND OPERATION INSTRUCTIONS — FENCE PROTECTION SYSTEMS
22
Figure 25. Pre-amp Pedestal Mounting
Transducer Cable Installation
Installation of Standard Coaxial Transducer Cable
Installation of the standard coaxial transducer cable is best accomplished with a minimum of two
people; one person to unreel the cable (see Figure 26) while the second person attaches the cable to
the fence. If the transducer cable must be installed by only one person, the procedure will be slower.
The transducer cable MUST be unrolled from the roll so that there are no kinks or spirals when the
cable is installed on the fence.
INSTALL NONSENSITIVE
CABLE IN CONDUIT
SIGNAL WIRING IN CONDUIT
TO CONTROL POINT
NOTE: PRE-AMP. ADAPTED
FOR CONDUIT FITTINGS
TSK JUNCTION BOX IN WEATHERPROOF
BELLBOX CONNECTS NONSENSITIVE CABLE
TO SENSITIVE CABLE OR HELISENSOR ON FENCE
PLACE PEDESTAL ON
NON-THREAT SIDE OF
FENCE
GROUND ROD PER THE
NATIONAL ELECTRIC CODE