pulseEKKO PRO
2-System Assembly and Startup
21
Figure 2-28: Attaching the Fibre Optic Remote Beeper/Trigger unit to the transmitter handle.
To connect the fibre optic remote beeper/trigger unit you should have the dual fibre optic cable for the
control module to transmitter connection plus a short single fibre optic cable (Figure 2-29). One of the two
cables on the dual fibre optic cable should already be connected to the
Input
(black) receptacle on the
transmitter.
Figure 2-29 illustrates the proper connection of the Fibre Optic Remote Beeper/Trigger unit. Ensure that:
1) The second fibre optic cable of the dual cable connects to the
Output
(grey) fibre optic
connector on the remote trigger and beeper unit. This connection enables the trigger part of the
remote beeper/trigger unit to work.
2) The short single fibre optic cable connects from the
Input
(black) fibre optic connector on the
remote trigger and beeper unit to the
Output
(grey) receptacle on the transmitter. This
connection enables the beeper part of the remote beeper/trigger unit to work.
Note that if you have a pulseEKKO 100 transmitter (Section 3.2.8: P41) you cannot use the
pulseEKKO PRO fibre optic beeper/trigger.