Multi-room mode
49
▷
Perform a walk test to check the transmission power (see „Performing
a walk test (reception quality)“).
▷
If necessary, re-adjust the transmission power and then repeat the
walk test.
▷
The master receiver must remain switched on for the following steps.
▷
Switch on all other receivers. These receivers synchronize with the
master receiver.
▷
Adjust all the receivers to the same transmission power as the master
receiver.
▷
Switch all receivers off and on again. Make sure the master receiver re-
mains switched on.
▷
After this rack has been configured, the receivers must only be
switched on and off together – not individually. Switch the complete
rack on and off using the on/off switch of the multi-outlet power strip.
▷
Switch off the rack in this room and repeat the above steps for config-
uring the rack in the next room.