background image

 

Preface

 

 
Dear Customer,

 

 
Thank you for purchasing this video server of the DIGILAN series from Security Center. You made the right decision 
in choosing this state-of-the-art technology, 

 

which complies with the current standards of domestic and European regulations. The CE has been proven and all 

related certifications are available from the manufacturer upon request.

 

To maintain this status and to guarantee safe operation, it is your obligation to observe these operating instructions! 
In the event of questions, please contact your local specialist dealer.

 

 
This video server is used for object surveillance. The recorded video signals are transmitted to a computer digitally 

via the connected network. The computer software permits simultaneous recording of up to 16 connected video 
signals. Data storage is subject to local national data-protection guidelines. Via the Internet Explorer, you have 
worldwide access to installed cameras (password-protected).

 

 

Precautions

 

 

The video server and connected components must be kept free of moisture (cellars and similar surroundings are to 
be strictly avoided). Use of this product for other than the described purpose may lead to damage of the product. 
Other hazards such as short-circuiting, fire, electric shock, etc., are also possible. The equipment is designed for 
operation using a Class 2 12V DC transformer. No part of the product may be changed or modified in any way. 
Connection to the public power network is subject to country-specific regulations. Please be aware of applicable 
regulations in advance.

 

 

 

To avoid fire and injury, please observe the 
following:

 

 
Securely fasten the device at a dry location in the 
building.

 

Ensure sufficient air circulation.

 

Do not expose the device to temperatures less than 
0°C or more than 50°C.

 

The device is designed for indoor use only.

 

Humidity must not exceed 90% (non-condensed).

 

Ensure that the voltage is disconnected when 
performing work on the device.

 

 
 
 
 

Please observe the following regulations to ensure 
trouble-free operation of your device.

 

 
The security video server is supplied by a 12V DC 
transformer. The transformer should be connected 
to the 230V AC building mains by means of a 
separate, electrically protected line.

 

Connection work to the building mains is subject 
to country-specific regulations.

 

 
 
 
 

 
 
 

General:

 

 
Improper or careless installation work may lead to faults and poor image quality. Therefore please read the 
instructions very carefully and follow the installation instructions for lines and components precisely.

 

 

2

Summary of Contents for TV7202

Page 1: ...Security Videoserver Installation instructions TV7202...

Page 2: ...ose may lead to damage of the product Other hazards such as short circuiting fire electric shock etc are also possible The equipment is designed for operation using a Class 2 12V DC transformer No par...

Page 3: ...deo server Read the Installation chapter carefully and follow the instructions contained in it to avoid damage caused by faulty assembly or incorrect installation This will ensure that the equipment g...

Page 4: ...FTP 20 UPnP and DDNS settings 22 Video 23 Motion sensor 25 Camera control 26 Modem 30 Application 31 Homepage layout 33 Viewing the log file 33 Viewing parameters 33 Factory settings 34 Deleting the...

Page 5: ...Scope of delivery Video Server TV7202 Transformer Software CD Installation instructions on CD 5...

Page 6: ...ications of UTP Category 5 CAT 5 and must not be longer than 100 meters Front BNC video input The video port with 75 Ohm resistor is used for connecting an analogue camera To ensure that the video mod...

Page 7: ...thernet interface regardless of any modem connection COM port If no Ethernet is available connect a modem cable or the null modem cable supplied to this serial RS232 port COM port to be able to use th...

Page 8: ...h LED status display Every time you start the video server it runs a self test The self test checks all hardware modules When the administrator connects the transformer both LEDs LED 2 3 under the net...

Page 9: ...ge in socket of the video server 12V DC Switching on Before installing further video servers make a note of the serial numbers for future reference Before connecting up all peripheral devices must be...

Page 10: ...k cable If your PC is not yet integrated into a network you first have to configure it for the network application Do this by opening the Properties page for your network This also applies if the came...

Page 11: ...start the program under Programs Installation Wizard 5 Following the program start the Installation Wizard automatically searches for a connected video server 6 If no video server is found in the firs...

Page 12: ...e IP address of the network adapter page 7 9 Now click to change the IP address or the subnet mask of the video server or network environment If you use a router in your network enter this IP address...

Page 13: ...ou can change the security settings to a lower level under Tools Internet Options Security Make sure you enable Active X Control Elements and Downloads Installing the plug in When you first access the...

Page 14: ...eges can only view the preset locations With the five buttons on the right of the picture the cameras can be controlled with other functions apart from pan tilt and zoom These should be preconfigured...

Page 15: ...rate The disadvantage of this protocol is that the realtime stream is worse than with the UDP protocol Use the HTTP protocol if the network is protected by a firewall and only the HTTP port 80 is to b...

Page 16: ...t date and time There are three ways of setting the system date and time The simplest way is to click Sync with computer time Or you can click Manual to set the date and time manually Note the date ti...

Page 17: ...cked the web browser prompts the administrator to enter the new password for accessing the equipment To add a new user enter the user name and password and click to confirm you input Up to twenty user...

Page 18: ...video server can be automatically restarted and operated The user can start the IP installation program to check the IP address assigned to the video server if this address was forgotten or if the UPn...

Page 19: ...ying the conditions defined Two file transfer methods are available e mail SMTP and FTP SMTP Domain name or IP address of the external e mail server Some SMTP servers require an account name for loggi...

Page 20: ...on to the primary server cannot be established In the case of the SMTP connection the video server automatically tries to set up the connection with the second SMTP server if the SMTP information ente...

Page 21: ...the IP address the subnet mask the default router and the DNS server are deleted if the network interface is changed For details on software installation see the corresponding section about Ethernet o...

Page 22: ...you enter a in this field you must enter a password in the next field To be able to use the DDNS service enter the password or the key Enables disables the UPnP function If UPnP is disabled the camer...

Page 23: ...and the visual effect Five options are available and requires the same bandwidth as and the size of the picture corresponds to the settings However the quality is not as good is particularly suitable...

Page 24: ...etween pictures Select to mirror the video picture vertically and horizontally Click to enable the motion sensor When this option is enabled the sensor fields are displayed with a red frame If this op...

Page 25: ...the mouse button pressed and drag the window to the required size A higher sensitivity detects smaller changes in the picture sequence If you raise the percentage you can distinguish better between sm...

Page 26: ...ternal serial port devices For details refer to the hardware description on connecting an RS485 device The camera control cable supplied can be used for Sony or Canon cameras The option in this driver...

Page 27: ...the camera view and the control buttons After moving the camera to the desired position enter the position name and click If you enter invalid characters in the position a warning message appears To...

Page 28: ...ASCII format The video server converts these into binary code and sends them via the serial port For example the string 8101ABCDEF is converted into five hexadecimal bytes 81 01 AB CD and EF The maxim...

Page 29: ...II format The video server converts the format in the ASCII command to binary format For example 012000ABCD from the COM port is sent as five hexadecimal bytes 01 20 00 AB and CD If the command string...

Page 30: ...ver sends no snapshots if an event occurs Enter the initial modem command after the prefix AT Select here between tone and frequency dialling means the number of times the video server should try to s...

Page 31: ...the FTP and SMTP servers may differ from those of the present Ethernet environment If the network interface is changed the administrator must first configure it The video server attempts to use the se...

Page 32: ...al applications according to personal requirements The video server monitors the channel and the digital input continuously Snapshots taken after an event can be configured so that they are delayed ac...

Page 33: ...c is not enabled the browser window is filled with the background colour The administrator can give the system logo a to link to another website You can set the and to get the best visual effects out...

Page 34: ...xternal server Via the FTP domain of the video server the administrator can update the configurations faster The files for designing the homepage GIF can be read and overwritten They can be loaded by...

Page 35: ...program change the working directory of FLASH BIN in the local folder 3 Connect to the video server with the user name root and the password 4 Upload FLASH BIN to the video server with the PUT command...

Page 36: ...ideo server sends the current state if the digital input After you enter dinote the following or similar is displayed DI L DI L If DI changes to HI only the following is displayed DI H Stopping inform...

Page 37: ...tion at the next start If you enter lock the video server locks the current network settings which are then used for the next session Resetting the network for new settings If you enter unlock the vid...

Page 38: ...null modem cable is connected Then both lower LEDs light up until the connection with the null modem has been established If a remote communications server is installed or an ISP service is used the...

Page 39: ...operational To avoid the risk of electric shock first connect the video server to the transformer before plugging the transformer into the 220 230V mains supply Software installation During the first...

Page 40: ...If Standard Modem Type is displayed under Manufacturer select Standard 33600 bps Modem under Models and click 40...

Page 41: ...Select the serial port COM1 or COM2 to which the null modem cable supplied is connected and click The null modem is now ready for operation Click 41...

Page 42: ...Creating a new connection After installing the modem open the Network Connections page under Windows to create a new connection Select Create a new connection and click 42...

Page 43: ...Select Connect to the Internet and click Select Set up my connection manually and click 43...

Page 44: ...Select Connect using a dial up modem and click Enter a name of your own choice and click 44...

Page 45: ...phone number and click The telephone number you enter is unimportant Enter the user name root The password is the one you changed previously or it is the default password the serial number of the vide...

Page 46: ...work Connections page open the new connection On the Networking tab under PPP Windows 95 98 NT4 2000 Internet Settings enable Enable software compression On the Networking tab enable Internet Protocol...

Page 47: ...null modem cable the administrator can open the default web browser Enter http 200 1 1 1 as address Note that 200 1 1 1 is used as the default IP address for a communications connection and 200 1 1 1...

Page 48: ...ess Access to the configuration page is reserved for the administrator only For modem operation further information is needed For details on further settings refer to the Modem section For details on...

Page 49: ...ccurs H Contact is closed during normal operation and and opens if an event occurs Example Enter http 192 168 0 201 setup setdo cgi do h in the address bar of the web browser Data deletion mode of ser...

Page 50: ...ing the system setup reset cgi Reboots the video server without warning URL pages The configuration page has a layout graphic with an options list and an options page The user is linked only to the op...

Page 51: ...ction setup motion html Image quality setup image html Application setup app html Homepage layout setup layout html System log setup logfile html Parameter list setup parafile html Delivery status fac...

Page 52: ...string shorter than 15 characters Add new user userpass text string shorter than 15 characters Define new user password deluser text string shorter than 15 characters Delete user action blank Validate...

Page 53: ...15 characters Password for secondary FTP server ftpfolder2 text string shorter than 40 characters Folder on secondary FTP server http number less than 65535 HTTP port controlport number less than 6553...

Page 54: ...ion preview not required Preview restore not required Restore original parameters save not required Save parameters Application settings via URL URL setup app cgi NAME VALUE EXPLANATION emode not requ...

Page 55: ...sequential mode send hh mm ss Stop time for sequential mode Homepage layout via URL URL setup layout cgi NAME VALUE EXPLANATION blank Define logo def Use default logo cuslogo url Use URL logo logourl...

Page 56: ...N and LED3 flashes U19 16C1550CJ P2 COM interface A fault in the Ethernet interface can refer not only to components on the PCB but also to the Ethernet cable or Ethernet connection B Frequently asked...

Page 57: ...ermits connection of more than one user You should install another web server to permit a larger number of users to retrieve the pictures from the video server F How fast is the video rate of the vide...

Page 58: ...cal data Audio 24Kbps 8Kbps optional Microphone One way microphone Frequency response 50 16000Hz S N rate above 60dB Alarm inputs outputs 1 sensor input max 12V DC 50mA 1 relay output max 24V DC 1A LE...

Reviews: