Edge
Smart Keypads and Card Readers
Direct Programming Manual
If you need help, please email
or call
(972) 474-6390
.
65
Each Wiegand input is configured to a different Wiegand bit format.
Each Wiegand input is configured for SBI Flex 64-bit format but with different code lengths.
Each Wiegand input is configured for a different Wiegand device type.
Disable Split-Relay Function
This procedure will disable the split-relay function.
1251
$
6
$
307
$
0
$
1251
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 307 and listen for status tones:
Good tone:
Split-relay function disabled
One tone:
Mode 1 enabled
Two tones:
Mode 2 enabled
Three tones: Mode 3 enabled
Enter next sub mode 0 and listen for good tone.
Enter Master Code (default 1251) again and listen for good tone.
Enter # key to exit Programming Mode.
Mode 1 (W1
$
A and W2
$
A)
When this mode is active, Relay A will be operated by both Wiegand inputs.
1251
$
6
$
307
$
1
$
1251
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 307 and listen for status tones:
Good tone:
Split-relay function disabled
One tone:
Mode 1 enabled
Two tones:
Mode 2 enabled
Three tones: Mode 3 enabled
Enter next sub mode 1 and listen for good tone.
Enter Master Code (default 1251) again and listen for good tone.
Enter # key to exit Programming Mode.
Mode 2 (W1
$
A and W2
$
B)
When this mode is active, Relay A will be operated by Wiegand Input 1, and Relay B will be
operated by Wiegand Input 2.
1251
$
6
$
307
$
2
$
1251
$
#