Edge
Smart Keypads and Card Readers
Direct Programming Manual
If you need help, please email
or call
(972) 474-6390
.
27
One or both Wiegand inputs are set to SBI Flex 64-bit format.
One or both Wiegand inputs are disabled.
One or both Wiegand inputs are configured to share code list with non-Wiegand codes.
Each Wiegand input is configured to a different Wiegand bit format.
Bulk Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers
This procedure will add sleep codes with a specified facility code in bulk for a Wiegand card
reader, remote, or vehicle tag reader. Only the 26-bit format can be used.
1251
$
6
$
102
$
3
$
XXX
$
XXXXX
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 102 and listen for good tone.
Enter next sub mode 3 and listen for good tone.
Enter 3-digit facility code and listen for good tone.
Enter 5-digit starting sleep code and listen for good tone.
Enter 5-digit ending sleep code and listen for good tone (maximum of 100 codes).
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
One or both Wiegand inputs are set to SBI Flex 64-bit format.
One or both Wiegand inputs are disabled.
One or both Wiegand inputs are configured to share code list with non-Wiegand codes.
Each Wiegand input is configured to a different Wiegand bit format.
Scan Entry for Wiegand Card Readers and Vehicle Tag Readers
This procedure will add one or more access codes with a specified facility code by scanning for a
Wiegand card reader or vehicle tag reader. Only the 26-bit format can be used.
1251
$
6
$
102
$
4
$
Scan First Card
$
...
$
Scan Last Card
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 102 and listen for good tone.
Enter next sub mode 4 and listen for good tone.
Scan card to be added twice at reader and listen for good tone.
Repeat above step to add additional codes.
Note: Card-to-card swipe timeout is 10 seconds.
Enter # key to exit Programming Mode.