Edge
Smart Keypads and Card Readers
Direct Programming Manual
If you need help, please email
or call
(972) 474-6390
.
37
Repeat above step to add additional codes.
Note: Card-to-card swipe timeout is 10 seconds.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
Wiegand input is set to SBI Flex 64-bit format.
Wiegand input is disabled.
Wiegand input is configured to share code list with non-Wiegand codes.
Split relay feature is enabled.
Add Latch Code(s) to Relay A on Wiegand Input 2
These procedures will add a latch code or codes to Relay A for Wiegand keypads, card readers,
remotes, and vehicle tag readers on Wiegand Input 2 only.
Quick Entry for Wiegand Keypad (uses default facility code)
This procedure will add one or more latch codes with the default facility code for a Wiegand
keypad. Both the 26-bit and SBI Flex 64-bit formats can be used.
1251
$
6
$
2
$
103
$
1
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 2 (for Wiegand Input 2). No tone will sound.
Enter next sub mode 103 and listen for good tone.
Enter next sub mode 1.
Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone.
Repeat above step to add additional codes.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
Wiegand input is disabled.
Wiegand input is configured to share code list with non-Wiegand codes.
Split relay feature is enabled.
Quick Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers
This procedure will add one or more latch codes with a specified facility code for a Wiegand card
reader, remote, or vehicle tag reader. Only the 26-bit format can be used.
1251
$
6
$
2
$
103
$
2
$
XXX
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.