![Seca mBCA 525 Instructions For Use Manual Download Page 17](http://html1.mh-extra.com/html/seca/mbca-525/mbca-525_instructions-for-use-manual_1230118017.webp)
Device overview • 17
17
-1
0-
05
-3
53
-0
02
g_
10
-2
02
0
B
No.
Control
Function
Handle
Transporting the device
Touchscreen display
Central control/display element
ON/OFF button with LED
LED white: Device on
LED green: Device on standby
LED off: Device off
Storage compartment
(
seca mBCA 525
only)
Transporting/storing the measuring mat (bioimpedance analysis)
Data transmission: Monitor/measuring mat
Charge measuring mat rechargeable battery
Power supply connection socket
For connecting the power supply cable
USB interface, 2 pcs
For transmitting data via a USB memory stick
For transmitting data between monitor and SmartBucket
For supplying SmartBucket with power
Connecting the scanner
ISIS interface
Advance feature for future system upgrade (currently no function)
LAN interface
For integrating the device in a network, using with the
seca analytics 115
PC software or with the
seca connect 103
software
for connection to an EMR system
Rechargeable battery
compartment
To take lithium-ion rechargeable battery supplied
Infrared interface
Automatic data transmission: Monitor/measuring mat (alternative if no
WiFi available)
Inductive charging interface with
magnetic catch
For charging measuring mat rechargeable battery (version-dependent)
seca 360°
internal wireless module
For connecting scales and length measuring devices from the
seca 360° wireless
system
Internal WiFi module
• For integrating the device in a network (using with the
seca analytics 115
PC software or with the
seca connect 103
software
for connection to an EMR system)
• For automatic transmission of data, monitor/measuring mat
SmartBucket (
seca mVSA 535
only)
For transporting/storing measuring equipment (bioimpedance analysis,
vital signs)
For storing consumables
Data transmission: Monitor/measuring mat
Charge measuring mat rechargeable battery
Connecting cable with
USB connector
For power supply and data transmission between monitor and
SmartBucket
Connection for temperature
measurement
For COVIDIEN
TM
FILAC
TM
3000 temperature probes
• Blue: Oral/axillary measurement
• Red: Rectal measurement
Probe holder
For COVIDIEN
TM
FILAC
TM
3000 temperature probes
• Blue: Oral/axillary measurement
• Red: Rectal measurement
Storage compartment for probe
covers
Capacity: 2 packs for COVIDIEN
TM
FILAC
TM
3000
Removable magazine holder for
probe covers
Capacity: 2 magazines for COVIDIEN
TM
GENIUS
®
3
Thermometer compartment
For COVIDIEN
TM
GENIUS
®
3 in-ear thermometer
Connection for temperature
measurement
For COVIDIEN
TM
GENIUS
®
3 in-ear thermometer
Sensor holder
For SpO
2
sensor
Connection for SpO
2
measurement
Depending on version, to fit:
• Masimo SET
®
patient cables and sensors (not illustrated)
• seca patient cables and sensors (shown in illustration)
Connection for blood pressure
measurement
For seca blood pressure cuffs