Section 3. Periodic Maintenance
17
Shutdown and Cleaning
IMPORTANT
Do not allow the laminator to sit idle without performing one of the following
cleaning procedures immediately after it is shut down.
Level 1 Cleaning
(Laminator will be used within 24 hours)
1. Ensure machine is in Stop mode.
2. Wipe off all traces of sealant from both Draw Down Bars with a wet cloth.
3. Wipe off all traces of sealant from any of the stainless steel parts around the
Draw Down Assembly.
4. Use a small cup of water to dip the tips of the flex hose into in order to clear the
hose of excess coating. Wipe the tip of the flex hose dry.
5. Dry off all parts that were cleaned with the wet cloth, especially the Draw Down
Bars.
6. Push any excess coating out of the Drain Tank if necessary.
Note:
Use a Scotchbrite™ green abrasive pad to remove dried sealant buildup
from bare metal parts. Do not attempt to clean painted or otherwise
coated parts with an abrasive pad.
7. Turn the machine OFF at the main power switch.
Summary of Contents for AquaSEAL SW-5000
Page 22: ...Section 4 After Sales Support 21...