950-0207revA - 20 - November 27, 2013
WIRING DIAGRAM
Bracket
Evaporator
3. Wiring of the Power Cord (single-phase).
CAUTION! The power supply for each indoor unit must be uniform.
a. Dismantle the cover of the electric box of the indoor unit.
b. Let the power cord go through the rubber ring.
c. Put the 4-core cable through the hole of the chassis and the bottom of the appliance upward,
and then connect the power line and the communication line from the outdoor unit to the
corresponding terminals N(1), 2, 3, and grounding terminal of the indoor unit. See Figure
20.Wiring shall be done properly as per the wiring diagram.
Note:
Be sure the wiring terminals A/B/C/D and piping joints A/B/C/D of the indoor unit match with
that of the outdoor unit respectively.
DO NOT CROSS WIRES
d. Fix the power cord tightly with the binding wire.
Note:
If the wall control need to be installed, please refer to the wall control manual 950-0210 placed in
the indoor unit for detail information of installation and setting.
Indoor Unit
Figure 20.