950-0207revA - 16 - November 27, 2013
● Take the drainpipe as short as possible and slope
downward at a gradient of at least 1/100 to prevent air
pockets. See Fig. 12.
●Insert the attached drain hose
completely into the drain socket. Tighten the attached clamp
within the range of gray sponge until the screw head is less than 0.16
” from the hose. See Fig. 13
and Fig. 14 below.
Clamp (accessory)
Sponge (gray)
Drain Hose
Large Sponge
accessory
(
)
Clamp
(accessory)
Max 0 16
. .
"
4
5
5
11
● Wrap the attached sealing pad
○
11
over the clamp and drain hose to insulate. See Fig. 14.
● No folding of drain hose inside the indoor unit. See Fig.15 below.
Watering can
Air outlet
2. Confirm that smooth drainage is achieved after the piping work.
Pour about 3.4 oz. water into the drain pan from the air outlet for confirming drainage. See Fig. 16
above.
CAUTION:
No water leakage is allowed on the joint of the condensate pipe.
Figure 12
.
Figure 13
.
(When drain hose is connected)
Incling the drain hose
Not to be lifted
No foldings
Not to be
soaking in water
Figure 14
.
Figure 15
.
Figure 16
.