3.2 Set-up\Pressures (with pressure transducer)
The display of menu 3.2 is conditioned by the method selected for the pressure control, parameter
2.4.
The pressure transducer is obligatory if the GEV valve is used.
.1 Static min.
xx.x bar
Minimum plant static pressure (range 12.0…45.0 bar)
Ã
Ä
2 Static max.
xx.x bar
Maximum static pressure (range 12.0…45.0 bar)
Ã
Ä
.3 Minimum
xx.x bar
Minimum plant pressure (range 05.0 … 45.0 bar)
Ã
Ä
.4 Maximum
xx.x bar
Maximum plant pressure (range 12.0…65.0 bar)
Ã
Ä
5 Full Load
xx.x bar
Full Load Pressure (range 12.0…45.0 bar)
Ã
Ä
.6 Overload
xx.x bar
Overload Pressure (range 12.0…45.0 bar)
3.2 Set-up\Pressures (with pressure gauges)
.1 Minimum
not called for
Minimum pressure gauge
•
Not called for
•
NA
contact
•
NC
contact
Ã
Ä
.2 Full Load
not called for
Full Load pressure gauge
•
Not called for
•
NA
contact
•
NC
contact
Ã
Ä
3 Overload
not called for
Overload pressure gauge
•
Not called for
•
NA
contact
•
NC
contact
Ã
Ä
4 Maximum
not called for
Maximum pressure gauge
•
Not called for
•
NA
contact
•
NC
contact