3.1.3 Settings \ Valve GEV \ Gains
.1 Gain
P: x
Gain P (range 0…9, standard set-point= 4)
Adjusts the response speed of the adjustment Increase if the plant is
low, decrease if the plant tends to vibrate
Ã
Ä
.2 Gain
I: x
Gain I (range 0…9, standard set-point= 0)
Adjusts the response speed of the adjustment Increase if the plant is
elastic, decrease if it is slow
Ã
Ä
.3 Gain
S: x
Gain S (range 0…9, standard set-point= 4)
Adjusts the departure response speed Increase if slow starting,
decrease if it jerks when starting
Ã
Ä
.4 Ratio
1:1 short
Cab/piston run ration and piston length
•
1:1
short
•
1:1
long
•
2:1
short
•
2:1
long
Ã
Ä
.5 Reset Gains
Reset the GEV adjustment gains to the standard values