![SEA STK3-GMV10 Manual For Installation And Use Download Page 48](http://html.mh-extra.com/html/sea/stk3-gmv10/stk3-gmv10_manual-for-installation-and-use_1220677048.webp)
SEA SYSTEMS
INSTALLATION AND USE
STK3-GMV10 Control panel and Pre-wiring
For Hydraulic Elevators
MSTK3-GB
Rev.04
05/02/12
© Sea Systems S.r.l.
Page 48 of 81
3.1 Settings \Valve GEV-DLV
This menu is displayed if the parameter 2.3 is set like GEV
3.1.1 Settings \ Valve GEV-DLV \ Ascent
.1 Ascent
Nom Speed:x.xx
m/s
Nominal ascent speed (range 0.2…1.00 m/s)
Ã
Ä
.2 Int. Ascent
Offset:
±
xx%
Correction of the intermediate ascent speed (range +20…+99)
STK3 automatically calculates the value of the speed during the runs
between neighboring floors.
This parameter allows the calculated speed to be modified in
percentages.
Ã
Ä
.3 Lev. Speed
Ascent:0.xx m/s
Ascending leveling speed. (range 0.04…0.20 m/s)
Ã
Ä
.4 Insp. Speed
Ascent:0.xx m/s
Ascending inspection speed (range 0.2…0.63 m/s)
Ã
Ä
.5 Ascent
Offset Vinsp:xx%
Ascending inspection speed during installation (range 01..99% of the
inspection speed 3.1.1.4)
Ã
Ä
.6 Ascent
Normal Acc.
Ascent Acceleration
•
Slow
Acc.
•
Normal
Acc.
•
Fast
Acc.
Ã
Ä
.7 Ascent
Normal Decel.
Ascent deceleration
•
Slow
Decel.
•
Normal
Decel.
•
Fast
Decel.
Ã
Ä
.8 Ascent
Soft Stop Normal
Soft Stop
•
Soft Stop Slow
•
Soft Stop Normal
•
Soft Stop Fast
Ã
Ä
.9 Ascent
t. Soft S.:x.x s
Soft Stop time at the end of operation in ascend (range 0.2…3.0 s)