67410182
The control unit is pre-set with the default settings, to start the control unit with the
DEFAULT settings just keep pressed the UP and DOWN buttons at the same time power
supplying the control unit the display shows the message
init
.
The DEFAULT settings are shown in the Menues table.
SELFLERNING OPERATION TIME WITH ENCODER
When an encoder is installed, it is necessary to select On in the
En(oder
menu, start programming and make sure
that leaf starts as first in closing. The gate will automatically execute the following cycle: CLOSING - OPENING -
CLOSING.
Note:
For stop detection sensitivity setting refer to the special menu.
SELFLEARNING OPERATION TIME WITH AMPEROMETRIC SENSOR
(For electromechanical motors only)
The times learning can be done only on electromechanical gates, taking advantage of the automatic detection of the
stops.
Once the programming has been started just make sure that the gate executes the following cycle: CLOSING -
OPENING - CLOSING.
Note:
For stop detection sensitivity setting refer to the special menu.
LEARNING WITH LIMIT SWITCH (WITH OR WITHOUT ENCODER)
When limit switches are mounted, the gate executes automatically the following cycle: CLOSING - OPENING -
CLOSING.
Before starting the learning, make sure (through the test menu), that the relative limit switches of every opening are
employed.
WORKING TIMES SELF LEARNING
U
WORKING TIMES SELFLEARNING THROUGH IMPULSES
ATTENTION: This procedure is potentially dangerous and should only be performed by qualified people in
safety conditions.
NOTE: The card is preset with the standard working times, therefore the automation can be started even
without the times programming, simply by adjusting the timing on the display (see default times).
1) Turn off electricity, release the motors and manually position the leaves on halfway.
Reset the mechanical lock.
2) Connect the control board to the power supply
3)
Select on the on-board display or JOLLY programmer, the type of motor that you are using as indicated in
the dispaly management.
4) If necessary also set the operation logic and the other parameters. If you want to program with a transmitter, store a
transmitter before programming.
5) Select
PROGra ing
on the display, press OK and than one of the UP or DOWN buttons.
(If the motor starts in opening, remove and re-put power supply, select on the display
reuerse otor
. And through
the UP and DOWN button put it on ON, or if you have the Jolly programmer, activate the motor exchange function. )
6) At this point the gate will start the following cycle: CLOSING - OPENING - CLOSING.
During cycle, to store the respective stops, press UP or DOWN or START at every point of stop of the leaf.
7) The self-learning is done.
U
U
English
GATE 1 DG R1
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
26
Rev.06 - 09/2014