67410182
25 - PKOTO2
26 - 24u avx
*
MENU SP
Default
SET
0 20
0.1
28 - OTOR RELEASE
U
Off
0.1 3.0
29 - BRAKE
*
OFF 100
%
1
Description
Set value
stop
OPEN NG
(LOS NG
Stop AND (LOSE
(LOSE
PAUSE RELOAD
Photocell active in closing
Photocell active before
opening
The photocell gives a
command to close during
opening, pause and
closing
The photocell charging the
pausing time
The photocell stops in closing
and closes when released
OPEN NG
ALUAYS
N (Y(LE
N pavsE
OPEN NG
(LOS NG
AUX output always
power supplied
AUX output power
supplied only during opening
AUX output power
supplied only during closing
AUX output power
supplied only during pause
AUX output active only
during cycle
POS T UE BRAKE
ANAGE ENT
U
U
NEGAT UE BRAKE
ANAGE ENT
U
U
Positive Electrobrake
Negative Electrobrake
27 - POS T ON RE(OUERY
Retrieves the inertia of the
motor after Stop or
reversing from 0 to 20 s
Disabled
Setting from 1 to 3
Adjusts the braking on the
limit switches
ALUAYS
0
Photocell active in opening
Skadou loop
avtotest
N (Y(LE AND
fototest
Security test
Security test with power
supply only during cycle
Until occupied, with open
gate, it prevents reclosing.
It is switched off during
closing.
off 8
30 - PER OD (AL pvshouer
off
Allows the repetition of the
Pushover functionat a
distance of time adjustable
from 0 to 8 hours at hourly
intervals
If the photocell is occupied
during opening, pause or
closing, the gate reopens
completely and closes
without observing the
pause time.
Delay pause ti e
u
English
GATE 1 DG R1
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
30
Rev.06 - 09/2014