Power supply connector
for control unit (230V)
23001158 (GATE 1 DG R1)
Motor wiring connector for control unit (230V)
23001158 (GATE 1 DG R1)
NN
RR
SS
TT
Three-phase
Motor (380V~)
N
N
N
N F
F
COM.
COM. OP.
OP. CL.
CL.
CN1
CN1
CN2
CN2
U
U
V
V
W
W
K2
K2
K1
K1
T1
T1
FST1
L
17 18 19 20
16
17
18
67410182
THREE-PHASE MODULE CONNECTION
Grounding
Three-phase
power supply
380V~
THREE-PHASE
MODULE
K1-K2 = Terminals 230V~ 16A
T1
= Thermal switch (limit 3,7A)
CN1
= Power supply connector for elect. control unit (220V)
CN2
= Power supply connector for three-phase
motor (380V)
FST1 = Grounding faston
Important note:
select in the settings of the motor menu the configuration “
Triphase - bvll
” , ref.. Pag.25.
Note 1
: If in the diagnostics shows "Max. cycles reached ", do the maintenance and / or reset the number of cycles performed
.
Note2:
To exit from the error messages, press OK. If the error persists, make all required checks for the specific error and / or disconnect the
device that generates the error to see if the error disappears.
At each opening and closing of the automation the flashing light will blink. It blinks once per second during opening and twice per second
during closing, while it remains lit during pause.
It is possible to view the alarms also on the flashing light or on the control lamp, simply by observing the number of flashes emitted and
verifying the reference in the table below:
ALARM DESCRIPTION
Signals
Kind of alarm
Solutions
FA LVRE OTOR
u
FA LVRE24
FA LVRE24UAVK
FA LVRE net
FA LVRE SELF TEST
FA LVRE L T SU T(K
U
FA LVRE FLASK NG L GKT
Motor current failure
24V Power supply
failure
AUX output voltage
Power supply failure
Self-test photocells failure
Limit switch
activation failure
Flashing lamp failure
Sure there are no short circuits on the motor or on the control unit.
Make sure there are no short circuits on the wiring or on the control unit
and no overloads.
Make sure there are no short circuits on wiring or control unit and no
overload.
Check the network or the F2 fuse
Check the photocells operation and / or connections on the control unit.
Check the operation of both limit switches and / or correspondence between
movement direction of the motor and engaged limit switches.
Check connections and / or conditions of the lamp.
Blinks
9
2
3
6
4
Blinks
5
7
6
4 fast
Cause of alarm
Motor failure
Photocell in closing
Photocell in opening
Collision in opening
Safety edge
Cause of alarm
Stop
Max. Cycles reached
Collision in closing
Limit switch fault