![Sea Recovery SRC Ultra Whisper Compact 200 Owner'S Manual Download Page 83](http://html1.mh-extra.com/html/sea-recovery/src-ultra-whisper-compact-200/src-ultra-whisper-compact-200_owners-manual_1221262083.webp)
Sea Recovery Ultra Whisper Rev. A
G. Connect all required hoses and tubes:
(** = Supplied by Installer or Owner; *** = Optional Accessory.)
1. Connect Feed and Fresh Water Flush Lines with the supplied 20 feet (6 meters) of 1/2” (12.7 mm) I.D. Inlet
Suction Hose. Secure the hose with two hose clamps offset 180 degrees at each fitting. Ignore any Optional
Accessory that is not to be installed:
Step from Outlet of
to Inlet of
1.
Feed Water Connector [3]
Sea Strainer [4]
2.
Sea Strainer [4]
***Inlet 3-Way Clean/Rinse Valve [36]
(left or right port)
3.
**Rinse/Clean bucket or container [38]
***Inlet 3-way Clean/Rinse Valve [36]
(left or right port)
4.
***Inlet 3-way Clean/Rinse Valve [36]
Feed Pump[6]
(center port)
5.
Feed Pump [6]
Fresh Water Flush Check Valve [35]
6.
Fresh Water Flush Check Valve [35]
***Plankton Filter [7]
7.
***Plankton Filter [7]
Prefilter 25 micron [13]
located on the left of the system frame
8.
**Unpressurized Potable Water Tank line [32]
Fresh Water Flush Pressure Pump [33]
9.
Fresh Water Flush Carbon Filter [34]
Fresh Water Flush Check Valve [35]
2. Connect Brine Discharge line with the supplied 20 feet (6 meters) of 3/8” (9.5 mm) O.D. Brine Discharge Tubing:
Step from Outlet of
to Inlet of
1.
ETD Port “S” [17]
***Discharge Rinse Clean Valve [37]
located inside the system frame
(center port)
2.
***Discharge Rinse Clean Valve [37]
**Rinse Clean bucket or container [38]
(left or right port)
3.
***Discharge Rinse Clean Valve [37]
Brine Discharge Connector [22]
(left or right port)
3. Connect Product Water line with the supplied 30 feet (9.14 meters) of 3/8” (9.52 mm) O.D. nylon tubing:
Step from Outlet of
to Inlet of
1.
Product Water Manifold Port “B” Unpotable
Brine Discharge Tee [22]
located inside the system frame
2.
Product Water Manifold Port “A” Potable
Charcoal Filter [28]
located inside the system frame
4.
Charcoal Filter [28]
***pH Neutralizing Filter [29]
5.
***pH Neutralizing Filter [29]
***U.V. Sterilizer [30]
5.
***U.V. Sterilizer [30]
**Potable Water Storage Tank Connector [31]
4. Connect Pressure pick-up with Pressure Gauges with the supplied 20 feet (6 meters) of 1/4” (6.35 mm) O.D.
nylon tubing:
Step from Outlet of
to Inlet of
1.
Feed Pump [6] Pressure Pick Up Tee
Inlet Compound Vacuum/Pressure Gauge [5]
located on feed water pump
located inside the system frame
H. Electrical Connections Refer To Section 8 of this Owner’s Manual
Section 2 Page 44 of 68
Summary of Contents for SRC Ultra Whisper Compact 200
Page 2: ......
Page 3: ...Ultra Whisper 200 600 Owner s Manual ...
Page 5: ...This page is intentionally blank ...
Page 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Page 12: ...Sea Recovery Ultra Whisper Rev A vii ...