IF The Pressure Gauges are all reading normal yet there is excessive Product Water Flow this could be caused by
an improper adjustment of the 3-way Product Water Diversion Solenoid Valve. If the 3-way Product Water
Diversion Solenoid Valve seats are improperly adjusted Brine Water can mix with Product Water. The
Product Water will be salty tasting.
0
-30
10
20
30
40
50
60
70
PSI
50
150
200
250
300
0
PSI
0
200
400
600
800
1000
1200
1400
PSI
PSI
0
300
250
200
150
100
50
IN Hg
100
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
b. POSSIBLE CAUSE: 3-way Product Water Diversion Solenoid Valve [26] is out of adjustment.
1) Check the salinity of the Product Water after the product water manifold and prior to the Charcoal
Filter [28] using a hand held TDS meter, or taste the Product Water to determine if it is salty, above
1000 PPM TDS.
2) If the Product Water salinity is greater than 1000 PPM TDS and is flowing greater than normal, check
the 3-way Product Water Solenoid Diversion Valve [26] to ensure that it is properly adjusted and not
allowing bypass between the “good” and “bad” product water ports. Refer to section 7 of this
manual.
section 6 page 28 of 38
Summary of Contents for SRC Ultra Whisper Compact 200
Page 2: ......
Page 3: ...Ultra Whisper 200 600 Owner s Manual ...
Page 5: ...This page is intentionally blank ...
Page 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Page 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Page 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Page 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Page 225: ...This page is intentionally blank ...
Page 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Page 298: ......
Page 299: ......