Sea Recovery Ultra Whisper Rev. A
9. The ***Plankton Filter [7] is mounted in an accessible location to a vertical surface between
the Feed Pump [6] Outlet and the Pre Filter [13] Inlet which is mounted to the System
Frame. Allow at least 4 inches (10 cm) of clearance below the bowl for element replacement.
CAUTION:
Feed water may spill during filter element replacing. Therefore, Do Not mount
the plankton filter above any electrical or electronic component.
10. The Pre-filters [13 & 14] are mounted to the System Frame. They may be removed from the System Frame
and mounted separately in an accessible location to a bulkhead. Allow minimum 4 inches (10 cm) below the
bowl for filter element removal.
CAUTION:
Feed water may spill during filter element replacing. Therefore, Do Not mount the prefilter above
any electrical or electronic component
11. The System Frame is mounted in an accessible location to a flat
surface allowing ease of access to controls and for maintenance.
12. The Charcoal Filter [28] is mounted in an accessible location to a vertical bulkhead. Allow
minimum 4 inches (10 cm) below the bowl for filter element removal.
CAUTION:
Product water may spill during filter element replacing. Therefore, Do Not
mount the charcoal filter above any electrical or electronic component
13. The ***pH Neutralizing Filter [29] is mounted in an accessible location to a vertical
bulkhead after the Charcoal Filter [28] and prior to the U.V. Sterilizer [30].
CAUTION:
Product water may spill during filter element replacing. Therefore, Do Not
mount the pH Neutralizing filter above any electrical or electronic component
14. The ***UV Sterilizer [30] is mounted to a bulkhead directly after the
Charcoal Filter [28], or after the pH Neutralizing Filter [29] if used. The
U.V. Sterilizer should be mounted vertically with the electrical fitting on the
top. The U.V. should be plumbed with the inlet on the bottom and the
outlet on top. Horizontal mounting is acceptable with outlet port on top
(pointed up) to displace air. Do Not mount the U.V. Sterilizer with the
electrical fitting on the bottom. Refer to Page 66 of this section for
installation details.
15. The ***Discharge Rinse Clean Valve [37] is mounted in an accessible location between the
System Brine Discharge Outlet and the Brine Discharge Thru-Hull Fitting [23]. Mount this
valve in an accessible location.
Section 2 Page 40 of 68
Summary of Contents for SRC Ultra Whisper Compact 200
Page 2: ......
Page 3: ...Ultra Whisper 200 600 Owner s Manual ...
Page 5: ...This page is intentionally blank ...
Page 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Page 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Page 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Page 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Page 225: ...This page is intentionally blank ...
Page 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Page 298: ......
Page 299: ......