1. Follow the procedures documented in the topic
Short-term Shutdown Procedure
on page 55.
2. Fill a container with 10 gallons (38 liters) of Fresh Product Water.
3. Add four (4) oz. of SRC SC to the container of Fresh Product Water.
4. Configure the System for a Recirculating Closed-Loop configuration as described in the topic
Closed-loop
Configuration
on page 54.
5. Start the System in MANUAL MODE.
6. Operate the System in the Recirculating Closed-Loop configuration for 10 minutes. After 10 minutes, STOP
the System.
Draining Component Water (for Winterizing)
If the System is, or will be, exposed to freezing temperatures, then components within the System's Post-Filtration
section must be drained of all Product Water.
1. Drain the Charcoal Filter and replace the element.
a) Remove the Charcoal Filter bowl.
b) Remove the water from the bowl.
c) Replace the Charcoal Filter Element with a new Charcoal Filter Element.
d) Place the bowl back onto the lid.
2. Drain the pH Neutralizing Filter.
a) Remove the pH Neutralizing bowl.
b) Remove the water from the bowl.
c) Place the bowl and pH element back onto the lid.
3. Drain the UV Sterilizer.
a) Disconnect the Product Water Line from the UV Sterilizer Filter.
b) Drain the Product Water.
c) Turn the System's power OFF.
d) Lock and Tag the Power Breaker to ensure that the System isn't turned back ON (which will displace the
Winterizing Mixture with Feed or Fresh Water).
e) Discard the Storage Chemical in an environmentally safe manner.
Cleaning the RO Membrane
Throughout its life cycle, the RO Membrane Element requires cleaning; the frequency of which depends on the
amount of production and salt-rejection loss (from normal, day-to-day use). At the element's end of life (EOL),
biological growth and salt accumulation make replacement necessary. To properly assess the RO Membrane
Element's performance changes, Sea Recovery Corporation strongly recommends that you maintain a daily log
of readings for comparison. When making performance comparisons, you must consider, and compensate for, the
following variables:
• Feed Water Temp
• Feed Water Salinity
• System Operating Pressure
After compensating for the preceding variables, a 10% decline in productivity (measured in GPH Flow), and/or a
10% increase in salt passage, indicate that the RO Membrane Element may need to be cleaned.
Important: If a dramatic drop in productivity is observed after the System has been in storage, it may indicate
that the RO Membrane Element has dried out and/or fouling has occurred. In this case, attempt to operate
the system for 48 (or more) continuous hours to saturate the RO Membrane Element's Product Water Channel.
If a dramatic drop in productivity is observed on a day-to-day basis, it may indicate non-cleanable fouling
91
General Operation
Summary of Contents for SRC Aqua Matic 1400-2
Page 2: ......
Page 3: ...Aqua Matic Compact 450 1800 Owner s Manual Manual PN B651140001 ...
Page 4: ......
Page 12: ......
Page 30: ......
Page 47: ...Commissioning 45 ...
Page 48: ......
Page 49: ...47 ...
Page 64: ......
Page 67: ...65 Commissioning ...
Page 68: ......
Page 75: ...73 ...
Page 96: ......
Page 125: ...123 ...
Page 134: ......
Page 137: ...Chapter 10 Appendix 135 ...
Page 138: ......
Page 139: ......
Page 140: ......
Page 142: ......
Page 143: ...Single Phase Electrical Motor Wiring 141 Appendix ...
Page 144: ...Three Phase Electrical Motor Wiring Aqua Matic Compact 450 1800 142 ...
Page 145: ...Three Phase Transformer Wiring 143 Appendix ...
Page 146: ...New System Initial Readings Form Aqua Matic Compact 450 1800 144 ...
Page 147: ...Daily System Readings 145 Appendix ...
Page 148: ......
Page 149: ...Chapter 11 Exploded Parts Views 147 ...
Page 150: ...Pre Installation Matrix Drawings Aqua Matic Compact 450 1800 148 ...
Page 170: ...Aqua Matic Compact 450 1800 168 ...
Page 175: ...2 8 11 5 10 7 9 3 16 4 15 6 14 13 12 17 22 21 20 19 19 18 24 23 173 ...
Page 177: ...2 8 11 5 10 7 9 3 6 4 15 12 13 14 19 18 23 24 21 20 17 16 22 175 ...
Page 179: ...2 4 3 19 15 11 12 9 10 8 14 17 16 10 13 5 6 18 7 21 20 177 ...
Page 181: ...21 3 2 18 14 10 11 7 16 15 9 12 4 5 17 20 19 8 6 13 179 ...
Page 183: ...2 4 3 18 14 21 11 9 10 8 13 16 15 10 12 5 6 17 7 20 19 181 ...
Page 185: ...9 16 3 7 4 5 2 13 12 14 15 17 28 27 19 11 10 6 25 26 23 1 29 8 24 183 ...
Page 187: ...9 15 3 7 4 5 2 13 12 14 26 25 17 11 10 6 23 24 21 1 27 8 22 185 ...
Page 189: ...9 15 3 7 4 5 2 13 12 14 26 25 17 11 10 6 23 24 21 1 27 8 22 187 ...
Page 191: ...25 23 24 9 16 8 22 20 19 3 28 17 14 12 1 2 7 30 11 10 6 21 29 26 13 4 5 18 27 189 ...
Page 193: ...23 21 22 9 15 8 20 18 17 3 26 14 12 1 2 7 28 11 10 6 19 27 24 13 4 5 16 25 191 ...
Page 195: ...23 21 22 9 15 8 20 18 17 3 26 14 12 1 2 7 28 11 10 6 19 27 24 13 4 5 16 25 193 ...
Page 212: ......
Page 213: ...Chapter 12 Electrical Diagrams Foldouts 211 ...
Page 216: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ......
Page 222: ......