4.3 - Electrical faults
Fault
Action
Measurements
Check/Cause
No voltage at
no load on
start-up
Connect a new battery
of 4 to 12 V to terminals
F- and F+, respecting
the polarity, for 2 to 3
seconds
The alternator builds up and its
voltage is still correct when the
battery is removed
- Lack of residual magnetism
The alternator builds up but its
voltage does not reach the rated
value when the battery is removed
- Check the connection of the voltage
reference to the AVR
- Faulty diodes
- Armature short-circuit
The alternator builds up but its
voltage disappears when the
battery is removed
- Faulty AVR
- Field windings disconnected
- Revolving field coil open circuit. Check the
resistance
Voltage too
low
Check the drive speed
Correct speed
- Check the AVR connections and settings
(AVR faulty)
- Field windings short-circuited
- Rotating diodes burnt out
- Revolving field coil short-circuited
- Check the resistance
Speed too low
Increase the drive speed
(Do not touch the AVR voltage pot. (P1)
before running at the correct speed)
Voltage too
high
Adjust AVR voltage
potentiometer
Adjustment ineffective
- Faulty AVR
- 1 faulty diode
Voltage
oscillations
Adjust AVR stability
potentiometer
If no effect: try normal/fast
recovery modes
- Check the speed: possibility of cyclic
irregularity
- Loose connections
- Faulty AVR
- Speed too low when on load
(or U/F knee-point set too high)
Voltage
correct at no
load and too
low when on
load (*)
Run at no load and
check the voltage
between F+ and F- on
the AVR
Voltage between F+ and F-
AREP/PMG < 10 V
- Check the speed
(or U/F knee-point set too high)
Voltage between F+ and F-
AREP/PMG > 15 V
- Faulty rotating diodes
- Short-circuit in the revolving field coil.
Check the resistance
- Faulty exciter armature
(*) Caution:
For single-phase operation, check that the sensing wires coming from the AVR are correctly connected to
the operating terminals.
Voltage
disappears
during
operation (**)
Check the AVR, the
surge suppressor, the
rotating diodes, and
replace any defective
components
The voltage does not return to the
rated value
- Exciter winding open circuit
- Faulty exciter armature
- Faulty AVR
- Revolving field coil open circuit or
short-circuited
- Overload (see LED)
(**) Caution:
Internal protection may be activated (overload, open circuit, short-circuit)
Caution: After operational testing or
troubleshooting, replace all access
panels or covers.
265/285
Summary of Contents for R 340 U
Page 1: ...User and maintenance manual for generating sets R340U 33504081101NE_0_1 ...
Page 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 285 ...
Page 18: ...Sockets voltage 208 120V 16 285 ...
Page 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 285 ...
Page 126: ...124 285 ...
Page 128: ...126 285 ...
Page 129: ...127 285 ...
Page 130: ...128 285 ...
Page 131: ...129 285 ...
Page 132: ...130 285 ...
Page 133: ...131 285 ...
Page 134: ...132 285 ...
Page 135: ...133 285 ...
Page 136: ...134 285 ...
Page 137: ...135 285 ...
Page 138: ...136 285 ...
Page 139: ...137 285 ...
Page 140: ...138 285 ...
Page 141: ...139 285 ...
Page 142: ...140 285 ...
Page 143: ...141 285 ...
Page 144: ...142 285 ...
Page 145: ...143 285 ...
Page 146: ...144 285 ...
Page 147: ...145 285 ...
Page 148: ...146 285 ...
Page 149: ...147 285 ...
Page 150: ...148 285 ...
Page 151: ...149 285 ...
Page 152: ...150 285 ...
Page 153: ...151 285 ...
Page 154: ...152 285 ...
Page 155: ...153 285 ...
Page 156: ...154 285 ...
Page 157: ...155 285 ...
Page 158: ...156 285 ...
Page 159: ...157 285 ...
Page 160: ...158 285 ...
Page 161: ...159 285 ...
Page 162: ...160 285 ...
Page 163: ...161 285 ...
Page 164: ...162 285 ...
Page 165: ...163 285 ...
Page 166: ...164 285 ...
Page 167: ...165 285 ...
Page 168: ...166 285 ...
Page 169: ...167 285 ...
Page 170: ...168 285 ...
Page 171: ...169 285 ...
Page 172: ...170 285 ...
Page 173: ...171 285 ...
Page 174: ...172 285 ...
Page 175: ...173 285 ...
Page 176: ...174 285 ...
Page 177: ...175 285 ...
Page 178: ...176 285 ...
Page 179: ...177 285 ...
Page 180: ...178 285 ...
Page 181: ...179 285 ...
Page 182: ...180 285 ...
Page 183: ...181 285 ...
Page 184: ...182 285 ...
Page 185: ...183 285 ...
Page 186: ...184 285 ...
Page 187: ...185 285 ...
Page 188: ...186 285 ...
Page 189: ...187 285 ...
Page 190: ...188 285 ...
Page 191: ...189 285 ...
Page 192: ...190 285 ...
Page 193: ...191 285 ...
Page 194: ...192 285 ...
Page 195: ...193 285 ...
Page 196: ...194 285 ...
Page 197: ...195 285 ...
Page 198: ...196 285 ...
Page 199: ...197 285 ...
Page 200: ...198 285 ...
Page 201: ...199 285 ...
Page 202: ...200 285 ...
Page 203: ...201 285 ...
Page 204: ...202 285 ...
Page 205: ...203 285 ...
Page 206: ...204 285 ...
Page 207: ...205 285 ...
Page 208: ...206 285 ...
Page 209: ...207 285 ...
Page 210: ...208 285 ...
Page 211: ...9 2 Appendix B Alternator user and maintenance manual 209 285 ...
Page 212: ...210 285 ...
Page 214: ...212 285 ...
Page 238: ...LEROY SOMER16015ANGOULÊMECEDEX FRANCE 338 567 258 RCS ANGOULÊME www leroy somer com 236 285 ...
Page 249: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 247 285 ...
Page 269: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 267 285 ...
Page 270: ...www leroy somer com 268 285 ...