Operating and Maintenance Manual
Scientek Washer Model SW-6000
Revision-3, Sept. 2007
5-19
5.3.1.9 Aqua Pulsing (Spraying Patterns)
Select a cycle for which you want to
select a new spraying pattern, using the
“NEXT CYCLE” button.
To select a spraying pattern for the cycle
press the button with the spraying pattern
description inside. Press repeatedly until
the desired spraying pattern appears on
the button.
Once you have selected the spraying
pattern you may want to setup times for
individual valves.
se “UP” or ”DOWN” button to highlight the valve whose time on you want to change. Press
HANGE VALUE” button to bring up a numeric keyboard where you can enter a new
ticular cycle press “ACCEPT” button
accept the changes or “CANCEL” button to cancel the changes.
ress “EXIT” button to go back to the Set-up menu screen.
U
“C
value.
After you have changed valve-time-on values for a par
to
Press “RETURN” button to go back to the Cycle Time menu screen.
P
Scientek Technology Corporation
Tel: (604) 940-8084
7943A Progress Way, Delta, BC V4G 1A3
Fax: (604) 940-8085