Operating and Maintenance Manual
Scientek Washer Model SW-6000
Revision-3, Sept. 2007
4-3
WARNING: BURN HAZARD
•
Allow unit to cool down before performing any service on pump,
piping and valves. Motor, pump, valves and piping surfaces become
very hot during unit operation
Wear gloves and face protection
4.4 REAR (CLEAN-END) CONTROLS
For machines which are supplied in a two-door configuration, a small auxiliary control panel
is installed on the clean-end of the machine. This control panel consists of the following
indicators/switches:
•
Cycle complete light – green illumination
•
Door open light – red illumination
•
Stop light – red illumination
•
Run light – amber illumination
•
Exhaust – amber illumination
•
Stop switch – as described in 4.2
•
Start switch – green momentary two-position push button switch, to re-energize
machine after “Stop” or to initiate start of cycle.
•
Exhaust switch – black momentary two-position push button switch, to initiate
additional exhaust venting time prior to unloading machine. This is an additional
exhaust time separate from normal time given at end of final rinse stage.
4.5 STRIP PRINTER
The strip printer is a panel mounted dot matrix printer. These printers record the activities
and settings of the machine through the wash cycle. For additional information regarding the
specific operation of the strip printer, refer to Appendix B.
Scientek Technology Corporation
Tel: (604) 940-8084
7943A Progress Way, Delta, BC V4G 1A3
Fax: (604) 940-8085