Operating and Maintenance Manual
Scientek Washer Model SW-6000
Revision-3, Sept. 2007
3-9
•
When the power drain timer has completed, the
gravity drain timer
is initiated. During
the gravity drain, the wash pump is deactivated and the drain valve remains open. This
allows any residual wash water in the sump, rotating arms and header to drain to the
sewer.
•
When the gravity drain timer has completed, the drain line valve remains open and the
unit proceeds to the next step.
•
The
RINSE 2
indicator display message, which has remained illuminated throughout this
section, is now deactivated.
WARNING: BURN HAZARD
•
Doors, washer interior and washed wares may be hot.
•
Hot water/steam may be sprayed through door opening if door is
opened too soon - press STOP button and wait until water flow stops
before opening door.
Wear gloves and face protection.
3.2.6 Exhaust
•
The unit is equipped with an exhaust duct for direct venting via power operated damper to
common house HVAC system, or via dedicated exhaust blower. In either case the P.L.C.
provides a dedicated signal to vent machine for timed period. The message display will
show exhaust time duration and will either command operation of damper or fan for given
time. When the exhaust timer signal is deactivated, the exhaust display is extinguished.
•
The
CYCLE END
indicator message is now activated and remains active until the unit is
started again or the POWER is turned OFF. If the controls are set to drain the unit, then
the drain line valve is open and the sump is empty. If the controls are set to retain the
final rinse, then the drain line valve is closed and the sump is full.
The unit can now be unloaded and is ready to start again.
•
•
Doors, washer interior and washed wares may be hot.
•
Hot water/steam may be sprayed through door opening if door is
opened too soon - press STOP button and wait until water flow stops
before opening door.
Wear gloves and face protection.
Scientek Technology Corporation
Tel: (604) 940-8084
7943A Progress Way, Delta, BC V4G 1A3
Fax: (604) 940-8085