FITTED UNITS
• This appliance is not designed to be used as a
tabletop appliance or inside a cupboard.
• This appliance is only intended to be fully fitted
into kitchen cabinetry.
• The fitted cabinet must not have a back wall
behind the appliance.
• A gap of at least 100mm must be maintained
between the wall and the base or back panel of
the unit above.
• The fitted cabinet must have a ventilation
opening of 250cm
2
on the front. To achieve this,
cut back the base panel or fit a ventilation grille.
• Ventilation slots and intakes must not be
covered.
• Safe operation of this appliance can only be
guaranteed if it has been installed in accordance
with these installation instructions.
• You are liable for any damage resulting from
incorrect installation.
• The cabinetry into which the appliance is fitted
must be heat-resistant up 90ºC
• When connecting to fixed wiring, a means for an
all pole disconnection with at least 3mm contact
separation must be incorporated in the fixed
wiring in accordance with the wiring rules. This
appliance should only be installed by qualified
persons.
min 100
Cupboard feet
Ventilation grid
min 100
50
460
250
INSTALLATION DIMENSIONS AND VENTILATION REQUIREMENTS
Note: There is to be a gap above the oven.
Front View
Side View
INSTALLATION