Maintenance and Care
28
01.00|HGN |en
Position of the position numbers
Fig. 8
1 Supporting ring (65)
2 Calibration arbor
(only for HGN 125/160)
3 Seal (15)
Compress the seal kidney shaped together (avoid sharp buckling).
Consider the position of installation! Calibrate after installation.
Screw tightening torques
Position of the position numbers
Item
HGN
80
100
125
160
10
21 Nm
21 Nm
42 Nm
100 Nm
11
6 Nm
21 Nm
21 Nm
21 Nm
34
21 Nm
21 Nm
42 Nm
100 Nm
Assembly and calibra-
tion of the bar seal
(15) inside the housing
9.5.2