Assembly
01.00|HGN |en
13
Assembly
Mechanical connection
WARNING
Risk of injury when the machine/system moves unexpectedly,
due to moving of gripping jaws.
• Before starting mounting of the gripper, the hydraulic connec-
tion must be switched off.
The values relate to the entire bolting surface.
Requirements for levelness of the bolting surface (Dimensions in mm)
Diameter
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
The module can be mounted from the front, from the rear or on
the side.
Fig. 1
mounting posibilities
1 2x cylindrical pins
DIN EN ISO 8734
2/4 4xSocket head cap screws
DIN EN ISO 4762
3 Adapter plate
5
2x Socket head cap screws
DIN EN ISO 4762
7
7.1
Check the evenness
of the bolting surface
Mounting
Summary of Contents for HGN 100