Assembly
20
01.00|HGN |en
Part gripped (O.D. gripping)
1 Assemble the proximity switch as previously described.
2 Set the gripper to the "Closed" position.
3 Loosen the set-screw which jams the control cam (therefore
remove the lateral sealing set-screw in the housing, 2 pieces
on each side).
4 Clamp the part to be gripped.
5 Push the control cam until the proximity switch is switching.
6 Carefuly set the gripper into “Closed” position.
7 Fasten the control cam and check on proper function.
8 Now close the lateral thread of the housing again with a seal-
ing set-screw.
NOTE
Consider the range of function of the control cams. Exchange them
if necessary
Chart of control cams:
Length of the
control cams
HGN
80 Stroke 1
100 Stroke 1
125 Stroke 1
160 Stroke 1
9.2 mm
0 - 5 mm
0 - 6 mm
0 - 4 mm
0 - 2 mm
14 mm
5 - 8 mm
6 - 10 mm
4 - 8.5 mm
2 - 6.5 mm
18 mm
-
-
8.5 - 13 mm
6.5 - 11.5 mm
24.5 mm
-
-
-
11.5 - 16 mm
Summary of Contents for HGN 100