Assembly and settings
24
01.00 | EGI | Assembly and Operating Manual | en | 1396645
5 Assembly and settings
5.1 Assembling and connecting
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
NOTE
A temperature malfunction may occur if the product reaches
excessively high temperatures.
• Ensure sufficient heat dissipation via the customer's mounting
surface.
• Mount the product so that sufficient cooling is guaranteed.
• The size of the cooling surface depends on the application.
Avoid exposure to additional heat e.g. caused by attachments
or by the attached axles.
Overview
Ø
Check the evenness of the mounting surface,
25].
Ø
Screw the product to the machine/system,
25].
✓
If necessary, use appropriate connection elements (adapter
plates).
✓
Observe the maximal tightening torque, admissible screw-in
depth and, if necessary, strength class.
Ø
Connect the ground cable between the product and the
machine/system,
Ø
Place the voltage supply cable on the connector and screw the
threaded ring tightly by hand,
26].
Ø
Plug the cable for the fieldbus onto the sockets and screw the
threaded ring in by hand,
the maximum tightening torque,
28].
Ø
If applicable: connect multiple products to each other,
Ø
Make sure that the connections are not stressed due to tensile
and pressure forces. Apply appropriate strain relief devices if
required.