Assembly and settings
26
01.00 | EGI | Assembly and Operating Manual | en | 1396645
Depth of engagement and tightening torque, product to adapter plate
Designation
EGI 80
Thread
M5
Minimum depth of engagement
[mm]
7
Maximum depth of engagement
[mm]
8
Centering sleeve [Ø]
8
Tightening torque [Nm]
9.0
Depth of engagement and tightening torque, finger to base jaw
Designation
EGI 80
Thread
M4
Minimum depth of engagement
[mm]
6.5
Maximum depth of engagement
[mm]
7.5
Centering sleeve [Ø]
6
Tightening torque [Nm]
4.5
5.2.2 Electrical connection
NOTICE
Risk of damage to the electronics!
A faulty connection can cause damage to the internal electronics.
•
The supply network must be a network of type "PELV" for
power and logic.
•
Observe the PIN assignment of the connecting terminals.
•
Make sure that all components are grounded correctly.